How Reliable Are Nitrogen Generators?
Nitrogen generator reliability is decided more by the air going in than by the generator itself. Keep that air clean and dry and keep up the servicing, and you've dealt with the failures most likely to shut it down. It will still stop now and then for maintenance or a fault, so the sensible step is to work out what a stoppage would cost you and hold only as much backup as that justifies.
What stops a nitrogen generator?
Most on-site generators use PSA, or pressure swing adsorption, where beds of carbon called a molecular sieve hold back the oxygen. Food gas guidance from EIGA, the European industrial gases trade body, runs through what can go wrong, and the failures that stop the plant start upstream of the sieve. A failed dryer lets condensate saturate the lower part of the sieve. A spent carbon filter lets oil vapour coat it. Either way the unit can no longer separate the gases and the plant shuts down.
EIGA's separate safety guidance adds dusting, where the sieve material slowly breaks down after many pressure cycles. Membrane generators have their own version of this, as the food gas guidance says their performance falls over time.
What goes wrong | What happens | What catches it |
Dryer fails | Condensate saturates part of the sieve and the plant shuts down | Dryer alarm and dew point monitoring |
Carbon filter is spent | Oil coats the sieve, separation fails and the plant shuts down | Planned carbon changes |
Sieve turns to dust | Performance drops, and dust can plug valves and instrument lines | Dust filter maintenance |
Membrane ages | Output or purity falls over time | A life-cycle plan for the membrane |
Oxygen analyser drifts | You can't trust the purity reading | Periodic calibration |
It's the same logic as the oil filter on a car: a small part changed on time protects a much bigger one. Our guide to compressed air filters explains what each stage removes.
How long does the sieve last?
Buyers often ask for a lifetime figure, but it's only as good as the conditions attached to it. Atlas Copco, whose range we supply and service, says a well-maintained sieve typically lasts 10 or more years. It ties that to inlet air quality, operating pressure and temperature, asks for 4 to 13 bar and 10 to 25°C with properly filtered and dried air, and warns that wet or dirty air shortens sieve life significantly.
That's a manufacturer's figure for one part. We haven't found an independent published figure for sieve life, or a reliable one for a whole generator. So ask for the expected life of your model in writing, with the inlet conditions it depends on.
What does nitrogen generator maintenance involve?
Mostly routine work on a schedule. The manufacturer's guide lists inlet filter replacement and regular monitoring of pressure, temperature and dew point sensors. The intervals come from the manual for your model, so ask to see that schedule.
EIGA's maintenance section is written for food use, but it makes a useful checklist for any site. It covers periodic functional checks of the shut-down system, checks on gauges, regulators, automatic valves and controllers, and calibration of purity analysers. It also says to check purity once the work is finished. Its worked example gives activated carbon a two-year operating life with the fill replaced based on analysis, which is an example rather than a rule.
The compressor, dryer and filters decide whether the generator stops, so plan them together. Our servicing and repairs work covers the compressed air equipment in front of the generator as well.
Two safety points belong here. EIGA's safety guidance notes that many generators sit idle but ready to restart by themselves, so they should be locked out before maintenance, with warning signs posted around them.
In Great Britain, the Pressure Systems Safety Regulations 2000 require a written scheme of examination for a pressure system used at work, unless each vessel is below 250 bar litres. A 500-litre receiver at 8 bar is 4,000 bar litres. A competent person decides what the scheme covers, including any vessels on the generator itself.
What would a stoppage cost you?
Start with an hourly figure you can defend, such as lost margin, wasted product and overtime to catch up. The flows, hours and costs below are illustrative, so put your own in. The cylinder figures come from BOC's nitrogen factsheet: a W cylinder holds 9.78 m³ and weighs about 85 kg, and a pallet of 15 holds 146.7 m³ and weighs about 1,500 kg.
Small site | Larger site | |
Nitrogen use | 5 m³ an hour | 15 m³ an hour |
Cover wanted | 8 hours | 16 hours |
Nitrogen needed | 40 m³ | 240 m³ |
W cylinders needed | 40 ÷ 9.78 = 4.1, so 5 | 240 ÷ 9.78 = 24.5, so 25 |
Weight of those cylinders | 425 kg | 2,125 kg |
Lost margin per hour | £150 | £400 |
Cost with no cover | £1,200 | £6,400 |
The small site has an easy decision, since five cylinders is a modest thing to keep against £1,200. The larger site needs a more careful look. Twenty-five loose cylinders are a handling job in their own right, and two pallets would give you 293.4 m³, which covers the 240 m³ with some to spare.
Ask your gas supplier what either option costs in rental, then set that against the £6,400. That factsheet covers a high-purity grade, so check the contents and grade of what you'd order. Cover hours should come from how long a repair would realistically take, so ask your service provider, us included, what to expect. A generator's everyday running cost is a separate sum, and our article on whether making your own nitrogen saves money covers that.
Is a backup only for breakdowns?
No. EIGA says on-site generators in food use should have a liquid or gaseous backup for maintenance or failure, for off-specification gas and for high peak demand. So a booked service counts, and so does a busy week when demand outruns the generator.
Delivered gas can let you down too. The manufacturer points out that a missed delivery or a shortage can put production at risk, so your backup stock needs watching like any other. The same page says a generator needs special measures for peak flows, such as a buffer tank. We haven't found a published rule for sizing that tank or the number of spare cylinders, so we'd work it out from your own peaks.
When can you get by with less?
EIGA's advice is written for food use. Elsewhere it comes down to your own sum, and you may need very little if:
a stoppage delays the work and doesn't stop it, for instance where the job can wait a day
you use nitrogen occasionally and can plan around a service visit
the cost of a day without gas is less than a year of cylinder rental
A second generator is hard to justify unless your stoppage figure is very high. And if the compressor is the weaker link, a spare generator won't help, because the generator stops when its air does. In that case, ask how compressor hire would work for your site.
What should you check on your own generator?
Most of these can be answered in an afternoon:
Who sees the dryer alarm, and how is dew point being recorded?
When were the filters and any carbon last changed, and what does the manual say?
When was the oxygen analyser last calibrated?
What happens to off-specification gas? Does the unit stop it reaching your process?
Can the unit restart by itself, and does everyone working nearby know that?
Is the air intake clear of boiler exhausts, solvents and cooling towers, as EIGA advises?
How much backup is on site, how long would it last and when did you last try the changeover?
A second opinion on your supply
Tell us which generator you have, when it was last serviced and what a day without nitrogen would cost you. We'll go through the likely weak points with you and how much backup looks sensible, including whether you're holding more than you need.
We've supplied and serviced compressed air equipment since 1991, and we're based at Stanton near Bury St Edmunds. Call us on 01359 251180 or contact us online.
Related Articles
We love to talk
Is there something we can help you with?
T: 01359 251180 E: web.enquiry@airpowereast.co.uk
About the author
Air Power East
Air Power East provides air compressor systems, industrial air compressor equipment and compressor maintenance services across the East Anglian region